DLR5040A-WE Non-CE
For prevention of human fastening errors and enhanced fastening management accuracy
- Ideally suited for the assembly lines of vehicles and electrical equipment requiring reliable screw fastening
- The controller receives signals from electric screwdrivers to provide highly reliable screw fastening control
- Count Return Function: When a screw is loosened, a reverse signal output from the electric screwdriver reverses the count by one
- The Count Correction Function does not count elevated screws or double fastening
– Input voltage range from 100 to 240 V AC is acceptable in any part of the world
(The screwdrivers to be used in combination with the counter require input power supplies that are written on the respective nameplate)
– Link Connection Function: You can build up a simple sequential screw tightening system by connecting the DLR5040A-WE screw tightening counters in series without using any external controller such as a programmable controller
– Driver Lock Function prevents unexpected start of screwdrivers
– Compact and Lightweight (Compared with our conventional models decreased by 30 % in volume and by 38 % in mass)
– SPC type screwdrivers for DLR5040A-WE are designed on the basis of established transformerless screwdrivers
Model : DLR5040A-WN
Count : 1 – 99
Counting Method : Count-up / Count-down
Count Correction Function : Count normal fastening only
Self Adjustment Timer Setting : 0.01 to 0.99 sec.
Work Detection Function : Yes (1 terminal) / No
External Count Input : 2 terminals (PARTS A / PARTS B)
Work Installation Timer Setting : 0 to 9.5 sec.
OK Outout Timer Setting : 0 to 9.5 sec.
NG Alarm : ON(1) / ON(2) / OFF
OK Buzzer : ON(1) / ON(2) / ON(3) / OFF
Count Return Function : ON / OFF
NG Judge Timing : WORK SET / DRIVER ON
Automatic / Manual OK Judge : AUTO / MANUAL
Screwdriver Lock Function : ON / OFF
Multiple Link : Up to 10 counters can be connected.
External Input on Terminal Block
: SENSOR / RESET / LINK-IN / PARTS A / PARTS B
External Output on Terminal Block : OK / NG / LINK-OUT
Parameter Memory
: Parameters stored in internal nonvolatile memory
Input Voltage : 100-240 V AC, 50/60 Hz
External Dimensions (mm[inch])
: W100 x D120 x H60 [W3.94″ x D4.72″ x H2.36″]
Mass (g[lbs]) : 470[1.04]
Accessories : 2 m Cord with UL three-prong plug.