DPE-800-7G 24V DC
Rated Voltage : 24 V DC
Flow Rate *1 : 800 mL/min
0.0283 cfm
Working Pressure Range : 0 to 100 kPa
0 to 1 bar
0 to 14.2 psig
Maximum Pressure *2 : 300 kPa
3 bar
42.7 psig
Maximum Current : 600 mA
Material of Wetted Parts
Cylinder Head and Head Cover : Polyamide (Nylon)
Diaphragm : Polytetrafluoroethylene
Valve and O-ring : Fluoro rubber
Duty Cycle : Continuous
Rated Performance(MTTF) *2 : 600 hours
Self-priming Pressure *1 : 40 kPa
0.4 bar
5.69 psig
Inlet : 5.4 mm O.D. straight barb
Outlet : 5.4 mm O.D. straight barb
Insulation Classification : E class equivalent
Mounting Dimentions : 74.5(L) x 41(W) mm
2-15/16″(L) x 1-39/64″(W)
Weight : 350 g (0.771 Lbs)
Motor : Brush DC Motor
*1 When the check valve is hardened due to low liquid temperature,self-priming performance and flow rate will go down.
*2 Restarting pumps with flow passage closed is impossible.
*3 Tubing between two pumping heads must be done in parallel.
Tubing in series between the two pumping heads should not be made. This may cause extreme pressure hike that will result in broken parts, liquid splash out or possible ignition.
Download
Basic information
Modal Name | Product code | Product No | JAN code | Group Name | Subgroub name |
---|---|---|---|---|---|
DPE-800-7G 24V DC |
40964
|
LB07430
|
4992338409647
|
Pumps & Compressors | Liquid Pump |
Reviews
There are no reviews yet.